List E - ExtrasHotel: Free trial / self auditexistingList E - ExtrasyesnopointsE1Wireless linked smoke detection system and internal alert system in every guest room (no points if E.03 is valid) 30E2Hotel partly equipped with automatic smoke detection and alarm system (no points if E.03 is valid) 50E3Hotel fully equipped with automatic smoke detection and alarm system 110E4Maintenance for smoke & fire detection and alarm system 0E5Hotel partly sprinklered (no points if E.06 is valid) 65E6Hotel fully sprinklered 165E7Maintenance for sprinkler system 0E8Automatic notification of the fire service is possible 10E9Special measures / alarms provided for guests with are not able to react on acoustic alarms 10E10Smoke compartment in horizontal escape routes not exceeding 30 metres 5E11Smoke compartment doors are self-closing 10E12Smoke compartment doors which are held open via magnetic devices and are closed via smoke & fire detection heads adjacent to the door 5E13Smoke compartment doors which are held open via magnetic devices can be closed via signal from the automatic smoke & fire detection system 10E14Maintenance for smoke compartment doors 0E15Smoke ventilation in escape routes 5E16Smoke ventilation in stairways (no points if E.17 is valid) 10E17Positive pressure in stairways 10E18Maintenance for smoke ventilation and/or positive pressure systems 0E19External escape stairs10E20Guest rooms are each fire- and smoke compartments 20E21Guest rooms separated by fire resistant walls 15E22Self closing guest room doors 10E23No basement 5E24Floors below ground floor isolated from the remainder of the stairwell by 2 doors 5E25Evacuation lifts 10E26Fire fighter lifts 10E27Fire-safety checks every 12 months 10E28Fire-safety checks every 24 months (no points if E.27 is valid) 5E29-0E30-0E31Fire prevention folder5E32Use of pictograms ; posted in the entrance hall 5E33Use of pictograms ; posted in each bedroom 5E34Emergency instructions given via TV upon arrival and on demand in local language and in appropriate foreign languages depending on the origin of the hotel's usual guests. 5E35Evacuation instructions via loudspeakers possible in local language and in appropriate foreign languages depending on the origin of the hotel's usual guests (no points if E.36 is valid) 5E36Automatic evacuation system 10E37Notification of emergency services via the European Emergency call number 112 can be dialled from every bedroom without prefix 5E38Escape hoods for every bed 10E39Additional information for guests, who need particular assistance in event of fire10E40Local fire service attendance time within 10 minutes with at least 6 fire fighters5E41"Guests register" with number of guests available at every time 5E42"Guests register" with number and location of guests who need assistance in the event of a fire 5E43Running cards - Orientation cards or equal means 5E44Exit route signage at low level 10E45Fixed hose reels EN 671/1 10E46Inspection of the electrical system every 12 months by a competent person 5E47Self-extinguishing TV 5E48Written instructions for the actions to be taken by hotel staff in case of an emergency 5E49Smoking policy strictly enforced 10E50Garbage policy strictly enforced 10E51Certified fire extinguisher of the aerosol type (sprays ) available in restaurant and kitchen 10E52Certified fire extinguisher of the aerosol type (sprays) available in guestrooms 10E53-0E54-0E55-0E56-0E57-0E58-0E59-0E60-0E61All staff has received basic instruction once 1E62All staff has received basic instruction every twelve months 5E6320% of staff has received practical fire extinguisher training once 5E6420% of staff has received practical fire extinguisher training once every 2 years 10E65Staff with specific fire protection tasks has received practical fire extinguisher training once 10E66Staff with specific fire protection tasks has received practical fire extinguisher training every 24 months 10E6710% of staff has received special instruction once 5E6810% of staff has received special instruction every twelve months 10E69All staff with specific fire protection tasks (including staff present at night) has received special fire prevention training 20E70All staff with specific fire protection tasks (including staff present at night) has received special fire prevention training every twelve months 20E71Person responsible for Fire Safety according to national standard / practice 15E72Additional Person responsible for Fire Safety according to national standard / practice 10E73Person responsible for Fire Safety according to national standard / practice refreshing every 3 years 25E74Additional person responsible for Fire Safety according to national standard / practice refreshing every 3 years 25E75Person responsible for Fire Safety according to national standard / practice refreshing every 5 years 15E76Additional person responsible for Fire Safety according to national standard / practice refreshing every 5 years 15E77Fire Safety Management Level (Advanced) 40E78Standard evacuation exercise performed every 12 months 10E79Standard evacuation exercise performed every 24 months (no points if E.78 is valid) 5E80Advanced evacuation exercise performed every 12 months 20E81Advanced evacuation exercise performed every 24 months (no points if E.80 is valid) 10E82Hotel Manager has received the F. S. hotel manager course refreshing every 5 years (no points if E.83 is valid) 5E83Hotel Manager has received the F. S. hotel manager course refreshing every 3 years 15E84Trained staff (minimum 1) available at any time on the premises (no points if E.85/E86 is valid) 5E85Trained staff (minimum 2) available at any time on the premises (no points if E.86 is valid) 10E86Trained staff (more than 2) available at any time on the premises 15 BemerkungenTotal 441 Download Artikel als PDF